Diffuse Reflectance Spectroscopy for Surface Measurement of Liver Pathology

Author

  • JAN NILSSON
  • Nina Reistad
  • Hannes Brange
  • Carl-Fredrik Öberg
  • Christian Sturesson

Summary, in English

BACKGROUND: Liver parenchymal injuries such as steatosis, steatohepatitis, fibrosis, and sinusoidal obstruction syndrome can lead to increased morbidity and liver failure after liver resection. Diffuse reflectance spectroscopy (DRS) is an optical measuring method that is fast, convenient, and established. DRS has previously been used on the liver with an invasive technique consisting of a needle that is inserted into the parenchyma. We developed a DRS system with a hand-held probe that is applied to the liver surface. In this study, we investigated the impact of the liver capsule on DRS measurements and whether liver surface measurements are representative of the whole liver. We also wanted to confirm that we could discriminate between tumor and liver parenchyma by DRS.

MATERIALS AND METHODS: The instrumentation setup consisted of a light source, a fiber-optic contact probe, and two spectrometers connected to a computer. Patients scheduled for liver resection due to hepatic malignancy were included, and DRS measurements were performed on the excised liver part with and without the liver capsule and alongside a newly cut surface. To estimate the scattering parameters and tissue chromophore volume fractions, including blood, bile, and fat, the measured diffuse reflectance spectra were applied to an analytical model.

RESULTS: In total, 960 DRS spectra from the excised liver tissue of 18 patients were analyzed. All factors analyzed regarding tumor versus liver tissue were significantly different. When measuring through the capsule, the blood volume fraction was found to be 8.4 ± 3.5%, the lipid volume fraction was 9.9 ± 4.7%, and the bile volume fraction was 8.2 ± 4.6%. No differences could be found between surface measurements and cross-sectional measurements. In measurements with/without the liver capsule, the differences in volume fraction were 1.63% (0.75-2.77), -0.54% (-2.97 to 0.32), and -0.15% (-1.06 to 1.24) for blood, lipid, and bile, respectively.

CONCLUSION: This study shows that it is possible to manage DRS measurements through the liver capsule and that surface DRS measurements are representative of the whole liver. The results are consistent with data published earlier on the combination of liver chromophores. The results encourage us to proceed with in vivo measurements for further quantification of the liver's composition and assessment of parenchymal damage such as steatosis and fibrosis grade.

Department/s

  • Surgery (Lund)
  • National Resource Centre for Physics Education
  • Atomic Physics

Publishing year

2016-09-23

Language

English

Pages

40-50

Publication/Series

European Surgical Research

Volume

58

Issue

1-2

Document type

Journal article

Publisher

Karger

Topic

  • Surgery
  • Radiology, Nuclear Medicine and Medical Imaging

Status

Published

ISBN/ISSN/Other

  • ISSN: 0014-312X