The browser you are using is not supported by this website. All versions of Internet Explorer are no longer supported, either by us or Microsoft (read more here: https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Please use a modern browser to fully experience our website, such as the newest versions of Edge, Chrome, Firefox or Safari etc.

Professor Malin Malmsjö, MD, PhD. Photo.

Malin Malmsjö

Professor

Professor Malin Malmsjö, MD, PhD. Photo.

Effects on heart pumping function when using foam and gauze for negative pressure wound therapy of sternotomy wounds

Author

  • Malin Malmsjö
  • Sandra Lindstedt Ingemansson
  • Richard Ingemansson

Summary, in English

Background: Negative pressure wound therapy (NPWT) has remarkable effects on the healing of poststernotomy mediastinitis. Foam is presently the material of choice for NPWT in this indication. There is now increasing interest in using gauze, as this has proven successful in the treatment of peripheral wounds. It is important to determine the effects of NPWT using gauze on heart pumping function before it can be used for deep sternotomy wounds. The aim was to examine the effects of NPWT when using gauze and foam on the heart pumping function during the treatment of a sternotomy wound. Methods: Eight pigs underwent median sternotomy followed by NPWT at -40, -70, -120 and -160 mmHg, using foam or gauze. The heart frequency, cardiac output, mean systemic arterial pressure, mean pulmonary artery pressure, central venous pressure and left atrial pressure were recorded. Results: Cardiac output was not affected by NPWT using gauze or foam. Heart frequency decreased during NPWT when using foam, but not gauze. Treatment with foam also lowered the central venous pressure and the left atrial pressure, while gauze had no such effects. Mean systemic arterial pressure, mean pulmonary artery pressure and systemic vascular resistance were not affected by NPWT. Similar haemodynamic effects were observed at all levels of negative pressure studied. Conclusions: NPWT using foam results in decreased heart frequency and lower right and left atrial filling pressures. The use of gauze in NPWT did not affect the haemodynamic parameters studied. Gauze may thus provide an alternative to foam for NPWT of sternotomy wounds.

Department/s

  • Ophthalmology, Lund
  • Thoracic Surgery

Publishing year

2011

Language

English

Publication/Series

Journal of Cardiothoracic Surgery

Volume

6

Document type

Journal article

Publisher

BioMed Central (BMC)

Topic

  • Surgery
  • Cardiac and Cardiovascular Systems

Status

Published

ISBN/ISSN/Other

  • ISSN: 1749-8090